600KW Power Resistive Load bank For Generator Testing

Qingdao Kingway Industry Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 600KW Power Resistive Load bank For Generator Testing from wholesalers
     
    Buy cheap 600KW Power Resistive Load bank For Generator Testing from wholesalers
    • Buy cheap 600KW Power Resistive Load bank For Generator Testing from wholesalers
    • Buy cheap 600KW Power Resistive Load bank For Generator Testing from wholesalers

    600KW Power Resistive Load bank For Generator Testing

    Ask Lasest Price
    Brand Name : Kingway
    Model Number : KL600
    Price : $17,265.00-18,782.00/sets
    • Product Details
    • Company Profile

    600KW Power Resistive Load bank For Generator Testing

    Product Description

    Product Application

    KL600 Automatic Load Bank Testing capacity 0-600KW

    Technical Parameters
    Model
    KL600
    Display accuracy
    Level 0.5
    Control Power
    External power 380VAC 3 phase 4 wire 50Hz
    Wire Connection
    Load bank input--busbar (star coupling "Y") Control power input--terminal block
    Communication Interface
    RS232/RS485
    Insulation
    F
    Way of Working
    Continuous Working
    Cooling
    Forced air, horizontal air intake and upwards exhaust cooling
    Transportation
    With lifting eyes and wheel castors
    Color
    As customer's requirements or as our design
    Dimensions
    1610*1250*1600mm L×W×H
    Weight
    800KGS
    Ambient Temperature
    -10°C~+50°C
    Relative Humidity
    ≤95%
    Altitude
    ≤2500m
    Atmospheric Pressure
    86~106kPa
    Contactor
    Schneider
    Fuse
    MIRO
    PLC
    Siemens
    Light Button
    ABB
    Relay
    OMRON
    Alloy Resistor
    Kingway
    Data Processing Software
    Kingway
    Functions
    1) 3 line LED multi-function meter can display real-time voltage and current of three phase and each phase, resistive power, power factor, apparent power, frequency and running time of generating set.
    2) User can pre-set the power then press the master load button.
    3) Control mode: user can choose local control or intelligent control (through PC)
    4) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
    Protection
    1) Have emergency stop button.
    2) In case of over-load, over-heat, short circuit, load bank will automatically remove load and give alarm.
    3) Fan protection: Load bank could not load before power of fan is on.
    4) Give alarm when any fan is abnormal or with insufficient air volume, etc.
    5) Protection button: there are some protection buttons can be switched off when false alarm or for special requirements.
    Data Processing Software
    1) Automatic load: User can set several periods of power and duration and in turn of 0%→25%→50%→75%→100% or 110% then →75%→50%→25%→0%.etc to make automatic load testing.
    2) Can make parallel testing for several units.
    3) Data can be saved, could display real-time data and history data.
    4) Charts and graphs can be exported in format of JPG while testing data exported in Excel and Word format, and all can be printed.
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    References Picture
    Meter Symbol Description: In the loading process, the machine can display real-time parameters by measuring instruments.
    Display instrument operating area, the key diagram is as follows: Instrument has the upper, middle and lower three display windows, each value and unit symbol form the data. For example, the upper window shows 100.0V, it is to say phase A voltage is 100V.

    F1, F2 and on the bottom, you can switch three windows and recycling display parameters.
    English symbols meaning:
    V: phase voltage symbol; Unit: V, and combined with K, M to kV MeV;
    V LL: two symbols denote a line voltage; Unit: V, and combined with K, M to kV MV;
    A: Current Symbol; Unit: A, and combined with K, M to kA, MA;
    W: active power symbol; Unit: W, and combined with K, M to kW, MW;
    Var: reactive power symbol; unit: Var, and combined with K, M to kvar, Mvar;
    VA: Apparent power symbol; Unit: VA, and K, M combination kVA, MVA;
    Hz: Frequency Symbol; Unit: Hertz;
    PF: Power Factor symbol;
    E: energy symbols; Unit: Ep (active power) kWh, Eq (reactive energy) kVAh, Es (apparent power) kVA;
    3P3L: 3-phase 3-wire two components;
    3V3A: 3-phase 3-wire three elements;
    3P4L: three-phase four-wire;
    600KW Power Resistive Load bank For Generator Testing
    Certifications
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    600KW Power Resistive Load bank For Generator Testing
    Quality 600KW Power Resistive Load bank For Generator Testing for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Qingdao Kingway Industry Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)